1976, Zeszyt 70-72
\ł'et Steam Discharge Coefficient of a Standard Nozzle and Orifice Plate
VLADIMIR KACER
Abstract
The methods of calculating the flow of wet steam for the standard nozzle and the orifice in the pressure range 0,05 - 50 bar and for the degree of dryness x> 0.8. Patterns were derived based on a uniform two-phase flow model, starting from the discharge coefficient for a single phase fluid. For the calculation of the flow rate used depending on the formal same as for single-phase flow.
Keywords: